Decoded: Why Barricade Devices? (May 2019)
Why would a school district consider using unregulated security devices, given the associated risk and liability? The answer may surprise you.
Why would a school district consider using unregulated security devices, given the associated risk and liability? The answer may surprise you.
Is an existing fire door assembly with 2 hinges acceptable, or should it be noted as a deficiency during a fire door inspection?
The fire marshal wants these stairwell doors to close more reliably than they do with the original system. Note the arched brick "frames" and the swing-clear strap hinges (cool, right??). WWYD?
Quick Question: Are steel, ball-bearing, butt hinges for fire door assemblies required to be UL listed?
I have spent two days trying to figure out what to write in this post. I'm still thinking.
It's almost time to submit change proposals for NFPA 80 and NFPA 105 - tell me what's on your wish list and I'll see what I can do to help!
Heads up - the 5-pound force limit on operable hardware is something everyone should be aware of long before the final inspection by the AHJ.
To bring more clarity, the Fire Protection Research Foundation has begun work on a full-scale fire test on fire doors with varying gaps between the door and frame.
Eric Laidlaw of Jensen Hughes sent me these Wordless Wednesday photos...I'd love to hear your theories/analyses of what's going on with this opening.
Have you ever run into a situation where a piece of hardware or a mortar box in a fire-rated frame prevented the GWB from penetrating 1/2-inch into the frame, as required by NFPA 80?
Follow-Up #1: For which types of hardware does NFPA 80 allow job-site preparations to be made in fire door assemblies?
If you're not in the habit of reading NFPA 80 cover-to-cover each time it is updated, this one might have slipped by you. It's an important change.
Remember when a fire alarm during the school day meant exiting immediately in an orderly fashion and enjoying a few minutes away from our desks? Times are changing.
When you're interpreting the code requirements for a particular building, how do you know which code or standard to reference?
The answer: In almost every US state. With that said, having it required by code and having it enforced by the AHJ are sometimes two different things.
It's that time of year again...when teachers get creative and their classroom doors become the canvas. Don't forget the rules of holiday door decorating!
I'd love to hear your thoughts on today's Wordless Wednesday photo. This is in direct conflict with everything I learned about life safety in hardware school.
It has been 74 days since I have written about classroom barricade devices. This refresher is posted by request, and in honor of Safe Schools Week.
Can less-bottom-rod (LBR) fire exit hardware with an auxiliary fire pin be installed on an existing fire door? If you have anything to add, please weigh in!
On a fire door assembly, is it acceptable to drill/cut a hole in the frame for the latchbolt, and not install the strike?
What's the proper protocol when a fire door assembly has been installed where it is not required? If you're considering the use of decomissioning labels, read this first.
This video does a great job of summarizing the code requirements that apply to glass and glazing used in fire door assemblies and egress doors. Thanks TGP!
Code issues are not uncommon in hotels, apartment buildings, and other residential occupancies. My next Decoded article addresses some things to look for.
Considering the liability a hotel could face if their fire door assemblies failed to perform during a fire, the repair methods employed by many hotels seem pretty irresponsible.
The British Woodworking Federation offers dozens of resources to increase awareness about fire door assemblies across the UK. What types of tools do we need in the US?
What happens to fire exit hardware during a fire test, and why doesn't the force of the hose stream actuate the touchpad and cause the door to unlatch?
This summer I visited quite a few colleges, and this dorm left me Wordless. :( Can you find all of the code-related issues with these fire doors and egress doors?
Could a locksmith be held liable for installing non-code-compliant hardware or will a facility manager face liability for failing to maintain openings in code-compliant condition?
During the discussions about yesterday's post someone mentioned the "sill" of the fire door assembly, which reminded me of a clarification that has been made in NFPA 80 in the 2016 edition.
When inspecting a fire door assembly, how do you measure the clearance at the bottom of the door when the clearance varies between the push side and the pull side?
This door with a mangled fire door label on the latch side was seen in a nursing home. Any theories about what happened here?
During a fire door assembly inspection, should a flashlight be used to verify whether the gasketing is continuous?
If I found this application in the field, I would contact the frame manufacturer and see if the application is allowed by their listing. I'm pretty sure the answer would be "no."
Just because closer reinforcements are not visible doesn't mean they aren't necessary! Yes - this is a fire door.
I just saw these doors in a hotel, so it seems like a good time to write about the requirements for doors at an elevator hoistway.
1) Are electromagnetic locks allowed to be used on fire door assemblies? 2) Do electromagnetic locks installed on fire door assemblies have to be labeled?
The School Superintendents Association (AASA) is sharing safety concerns about classroom barricade devices with their 13,000+ members. Visit iDigHardware to get a copy of the document that is being distributed.
I'm confused about this conflict between newly-adopted code requirements and what the media is reporting. Can anyone share some insight?
What do you think the wood strapping is for?
When I first started working in the door and hardware industry, I learned all about the rules that apply to fire doors, but I didn’t fully appreciate the value of a closed door during a fire.
Watching this news report brought a little tear to my eye. FINALLY, someone in the media is talking about both sides of the equation - safety AND security.
A new package of fire safety laws has now been approved and is on the mayor's desk awaiting his signature...
As hopefully most of you know by now, corridor doors in health care facilities are required by NFPA 101 to have positive-latching hardware. Lance Werner of Allegion sent me this photo of a pair of fire doors in a nursing home, leading to a linen storage room. A Schlage LM9200 would have been a much better solution.
This is what I've been saying all along. Why has it taken so many deaths and injuries to get people to pay attention?
So let's say that I'm thinking about renting out my college-bound daughter's bedroom on Airbnb to help offset the cost of her books and fees. Does her bedroom door need to be a fire door? Is my house now a small hotel?
This video from a recent fire in a dormitory at Idaho State University really shows the difference that a closed door can make.
I'm hoping this piece sums up the concerns associated with classroom barricade devices and can be used as reference material when discussing options for school security.
In an emergency, the ability to quickly evacuate can be key to survival. Life safety is everyone's responsibility. If you see something, say something.
I don't have an attached garage, but if I did, I would make sure that the door is self-closing or automatic-closing. Is this something you have considered for your own home?
I'm just going to admit it - I'm confused - and I'm hoping that someone who works more closely with the Joint Commission can help to clear this up. The Joint Commission recently distributed a document giving notice of 3 changes to their standards; 2 of the changes involve doors, and the effective date is March 11, 2018.