QQ: Field Preps for Auxiliary Fire Pins
Can less-bottom-rod (LBR) fire exit hardware with an auxiliary fire pin be installed on an existing fire door? If you have anything to add, please weigh in!
Can less-bottom-rod (LBR) fire exit hardware with an auxiliary fire pin be installed on an existing fire door? If you have anything to add, please weigh in!
On a fire door assembly, is it acceptable to drill/cut a hole in the frame for the latchbolt, and not install the strike?
What's the proper protocol when a fire door assembly has been installed where it is not required? If you're considering the use of decomissioning labels, read this first.
This video does a great job of summarizing the code requirements that apply to glass and glazing used in fire door assemblies and egress doors. Thanks TGP!
Code issues are not uncommon in hotels, apartment buildings, and other residential occupancies. My next Decoded article addresses some things to look for.
Considering the liability a hotel could face if their fire door assemblies failed to perform during a fire, the repair methods employed by many hotels seem pretty irresponsible.
The British Woodworking Federation offers dozens of resources to increase awareness about fire door assemblies across the UK. What types of tools do we need in the US?
What happens to fire exit hardware during a fire test, and why doesn't the force of the hose stream actuate the touchpad and cause the door to unlatch?
This summer I visited quite a few colleges, and this dorm left me Wordless. :( Can you find all of the code-related issues with these fire doors and egress doors?
Could a locksmith be held liable for installing non-code-compliant hardware or will a facility manager face liability for failing to maintain openings in code-compliant condition?
During the discussions about yesterday's post someone mentioned the "sill" of the fire door assembly, which reminded me of a clarification that has been made in NFPA 80 in the 2016 edition.
When inspecting a fire door assembly, how do you measure the clearance at the bottom of the door when the clearance varies between the push side and the pull side?
This door with a mangled fire door label on the latch side was seen in a nursing home. Any theories about what happened here?
During a fire door assembly inspection, should a flashlight be used to verify whether the gasketing is continuous?
If I found this application in the field, I would contact the frame manufacturer and see if the application is allowed by their listing. I'm pretty sure the answer would be "no."
Just because closer reinforcements are not visible doesn't mean they aren't necessary! Yes - this is a fire door.
I just saw these doors in a hotel, so it seems like a good time to write about the requirements for doors at an elevator hoistway.
1) Are electromagnetic locks allowed to be used on fire door assemblies? 2) Do electromagnetic locks installed on fire door assemblies have to be labeled?
The School Superintendents Association (AASA) is sharing safety concerns about classroom barricade devices with their 13,000+ members. Visit iDigHardware to get a copy of the document that is being distributed.
I'm confused about this conflict between newly-adopted code requirements and what the media is reporting. Can anyone share some insight?
What do you think the wood strapping is for?
When I first started working in the door and hardware industry, I learned all about the rules that apply to fire doors, but I didn’t fully appreciate the value of a closed door during a fire.
Watching this news report brought a little tear to my eye. FINALLY, someone in the media is talking about both sides of the equation - safety AND security.
A new package of fire safety laws has now been approved and is on the mayor's desk awaiting his signature...
As hopefully most of you know by now, corridor doors in health care facilities are required by NFPA 101 to have positive-latching hardware. Lance Werner of Allegion sent me this photo of a pair of fire doors in a nursing home, leading to a linen storage room. A Schlage LM9200 would have been a much better solution.
This is what I've been saying all along. Why has it taken so many deaths and injuries to get people to pay attention?
So let's say that I'm thinking about renting out my college-bound daughter's bedroom on Airbnb to help offset the cost of her books and fees. Does her bedroom door need to be a fire door? Is my house now a small hotel?
This video from a recent fire in a dormitory at Idaho State University really shows the difference that a closed door can make.
I'm hoping this piece sums up the concerns associated with classroom barricade devices and can be used as reference material when discussing options for school security.
In an emergency, the ability to quickly evacuate can be key to survival. Life safety is everyone's responsibility. If you see something, say something.
I don't have an attached garage, but if I did, I would make sure that the door is self-closing or automatic-closing. Is this something you have considered for your own home?
I'm just going to admit it - I'm confused - and I'm hoping that someone who works more closely with the Joint Commission can help to clear this up. The Joint Commission recently distributed a document giving notice of 3 changes to their standards; 2 of the changes involve doors, and the effective date is March 11, 2018.
Our newest whiteboard animation video addresses the important topic of classroom security.
Does NFPA 80 allow small signs on fire door frames? Are there limitations on the size, material, and method of attachment?
Since it's Wordless Wednesday, here is a photo that Jim Phillips of SBS Associates sent me from a school walk-through. Luckily the school's security precautions kept these intruders out.
One of the most frequently-cited products seems to be the door loop or door cord. In order to address this problem, Schlage series 788 and 789 armored door cords are now classified by UL to UL 10C, and are acceptable for use on fire door assemblies.
You have all heard me talk about how important it is to sleep with your bedroom door closed at night - to benefit from the protection provided by a closed door. I've been writing about fire doors on iDigHardware for 9 YEARS(!), trying to inform as many people as possible about the purpose of fire doors, why they need to be closed and latched when a fire occurs, and what is involved with an annual fire door inspection.
Should "missing" screws in a parallel-arm shoe be cited as a deficiency during a fire door inspection?
The increased enforcement of the inspection requirements for fire door assemblies has brought some pretty intense scrutiny upon the various components. In some cases we're finding that NFPA 80 and the model codes don't currently address the fine details of how these assemblies are tested and constructed.
Are you familiar with Technical Glass Products (TGP)? They're now part of our Allegion family! Here's the latest news...
The extended deadline has now passed. Facilities that receive funding from Medicare and/or Medicaid must have fire door assembly inspections conducted annually and documented, with any deficiencies repaired "without delay."
I suspect that many of you already know what the topic of today's post will be; many readers sent me links to news reports on last week's fire in a Bronx apartment building.
I just saw an article in the Preston Blog, about a fire in a block of student apartments that was contained by a closed and latched fire door assembly in a fire barrier.
I know some of you are good at hardware forensics...what was the motivation for this and what modifications were made? BTW...this is a fire door.
If I have a pair of doors leading to a stairwell, do both leaves have to allow reentry?
This is our big chance to propose some changes to the IBC, to help make it easier to interpret, and to address new developments in products or technologies, or new safety issues that have arisen...
While ensuring code-compliance, of course!
Our last whiteboard animation video for this year will address the 2018 model code requirements for classroom security...
When Good Morning America starts talking about closing doors, you know this important advice will (finally!) start to reach the masses. Check out this UL test and see the amount of protection provided by the closed doors, and share it with your friends and loved ones using the Share/Save icon above...
You may remember that I'm working on a series of online code classes, which will be available early in 2018. To support those classes, I am updating some of my past Decoded articles to include revisions from new editions of the codes and standards. Here is the latest information regarding alterations of fire door assemblies.