Andrew Haring of Frameless Hardware Company sent me a reel (starring Jeff Vazquez of JV Glass Co.) for today’s Wordless Wednesday post, and there are several problems with this application.

The signage about the door remaining unlocked is required by code when a key-operated locking device is installed.  The door in question does have a key-operated deadbolt but also has panic hardware.  Typically, the key-operated (double-cylinder) deadbolt is installed as an alternative to the panic hardware in certain applications, not in addition to the panic hardware.  I think this needs more clarification in the code – I wrote about it here.

A double-cylinder deadbolt/key-operated lock is permitted for doors serving exterior spaces where the egress path passes through the interior of the building, but would require a two-way communication system on the egress side of the door.  The lock would also need to be one that is “readily distinguishable as locked” – I recommend an indicator deadbolt.

And the biggest problem of all…the door is locked while the outdoor space is occupied!

You can read more about the requirements for key-operated locks here, and for securing exterior spaces here.

You need to login or register to bookmark/favorite this content.