Schlage L909xI don’t know about you, but once a product number takes root in my head I have a tough time getting used to a new one.  I’ve still got numbers in there from the 80’s!  But it’s time to do a memory upgrade because the Schlage L9080-EL and L9080-EU locksets have been replaced with a series of new and improved electrified mortise locks.

  • Current draw has been reduced – now 0.4 amp max current draw, 0.010 amp holding current, which allows multiple locks to be connected to a single power supply.The lock’s electronics autodetect 12 & 24VDC, so a single chassis accommodates multiple supply voltages.
  • A case-mounted switch allows field section of EL or EU operation without opening the chassis.
  • A new RX (request-to-exit) module with an improved design can be added without opening the case.
  • Six functions are available for application flexibility.
  • Allegion Connect molex system is standard for all locks in this series.
  • UL listed for a 3-hour fire door, and listed to UL 294 – Standard for Access Control System Units.

Here are the product numbers:

No Cylinders

  • L9090EL/EU: outside lever locked, inside lever free egress
  • L9091EL/EU: both levers locked

One Cylinder

  • L9092EL/EU: outside lever locked, inside lever free egress (replaces L9080EL/EU)
  • L9093EL/EU: both levers locked

Two Cylinders

  • L9094EL/EU: outside lever locked, inside lever free egress
  • L9095EL/EU: both levers locked (replaces L9082EL/EU)

Keep in mind that locking the egress side lever is only allowed in very limited circumstances for egress doors.  Another consideration is that the lock is now field selectable (fail safe / fail secure), so it’s very important to make sure that the lock is installed with the correct function – especially for doors that require fail safe locks for stairwell reentry.

Click here to download the data sheet for this product.