Last week I spent some time doing training in an office building, where I noticed these doors in the corridor leading to the office suites.
Does anyone see a code issue here? WWYD?
You need to login or register to bookmark/favorite this content.
What is approach clearance for 200
I take rated doors
Top office door appears to have electric strike
Not sure why the stair door opens in??? Maybe only accesses roof????
Plus if office door is required exit,, stair door blocks egress, when opened.
No fire sprinklers??? Older building??
Wonder on top picture,,, door bumper appears useless, to far away
Viewers want to know
Approach clearances! Oy.
approach side clearance
Door adjacent glass is wired which is no longer allowed. Glass should be tempered based on door and floor proximity, and fire rated glass if that is a fire wall.