4A – Introduction to Life Safety and Egress

This section of the ShortCodes course will cover the code requirements related to life safety and egress.  Egress is the action of going out or leaving a place, and the means of egress describes the route that a building occupant travels along the exit access and the exit, to the exit discharge.

In most buildings, the doors within the means of egress must allow building occupants to exit freely; people can not be locked inside of a room or building except in locations specifically allowed by code.  One example of this would be certain types of units within health care occupancies, where patients require containment for their safety or security.  In these areas, such as memory-care facilities, doors are allowed to prevent egress until emergency evacuation is needed.  This application has become known as “controlled egress.”

Most of the egress requirements are found in Chapter 10 of the International Building Code (IBC) and the International Fire Code (IFC), and in Chapter 7 of NFPA 101 – The Life Safety Code.  The video below is an introduction to the egress requirements for door openings. Most of the concepts addressed in the introductory video are covered in more detail in other segments of the ShortCodes course.

After watching the video, proceed to the review questions below.

~~~

Review Questions

1. Which doors in a means of egress are required to swing in the direction of egress?

  1. All egress doors must swing in the direction of egress.
  2. Doors serving 10 people or more
  3. Doors serving 50 people or more
  4. Doors serving 100 people or more

2. The model code requirements of 15 pounds to release the latch, 30 pounds to set the door in motion, and 15 pounds to open the door to the fully-open position apply to which doors?

  1. Manually-operated exterior doors and fire doors
  2. Non-fire-rated swinging doors
  3. Automatic doors
  4. All egress doors

3. Which doors in a means of egress are NOT required to be unlatched with one releasing operation?

  1. Classroom doors
  2. Patient room doors
  3. Electrical room doors
  4. Dwelling unit entry doors

Answers: 1 – C, 2 – A, 3 – D

~~~

Return to the ShortCodes menu.

Download the Allegion Code Reference Guide.

Leave a Reply



This website or its third party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy. By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.

This website or its third party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy. By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.