Gasketing on Stair Doors

If you read this paragraph in a vacuum, it seems like all fire doors have to limit the air infiltration to this level (in most cases this would require gasketing), but this paragraph falls under section 716.5.3 - Door assemblies in corridors and smoke barriers. There are two sections following 716.5.3 that apply to other types of fire doors...

By |2021-07-05T16:24:48-04:00August 25th, 2014|Fire Doors, Gasketing & Thresholds, Smoke|20 Comments

FF: 5 Operations to Exit

Eric Rieckers of Yadon Construction Specialties sent me this classic Fixed-it Friday photo of a door gone wrong. Security must not be enhanced at the expense of life safety, and doors in a means of egress must be unlatched with one operation. Several of these locks are also mounted outside of the allowable range for operable hardware.

By |2014-08-19T16:36:44-04:00August 22nd, 2014|Fixed-it Friday, Locks & Keys, Means of Egress|16 Comments

FF: Essaouira, Morocco

And now...for my last post from Morocco, some Fixed-it Friday photos from Essaouira. If you've never visited, it is a beautiful city with an old fort, a busy port, talented wood carvers, a sandy beach, fresh seafood, and the fattest cats in all of Morocco. Oh - and lots of doors that are fighting corrosion from the salt air. Enjoy!

By |2017-07-28T09:52:19-04:00August 14th, 2014|Beautiful Doors, Fixed-it Friday, Road Trips|3 Comments

Decoded: Fair Housing Act

A common misconception is that the Fair Housing Act applies only to federally-funded housing projects, but according to the US Department of Housing and Urban Development, “The Fair Housing Act requires all ‘covered multifamily dwellings’ designed and constructed for first occupancy after March 13, 1991 to be accessible to and usable by people with disabilities. Covered multifamily dwellings are all dwelling units in buildings containing four or more units with one or more elevators, and all ground floor units in buildings containing four or more units, without an elevator.”

By |2021-06-14T20:12:40-04:00August 10th, 2014|Accessibility, Articles|1 Comment

FF: Communicating Door Closers

Today's my birthday!! David Barbaree of St. Vrain Valley School District sent me this present...a special application for closers on communicating doors - two doors in one frame. Communication doors are usually found between hotel rooms and do not have door closers, but in this case the two doors are the exterior doors for a school kitchen...

By |2014-07-28T09:09:44-04:00August 1st, 2014|Door Closers, Fixed-it Friday|32 Comments